Our range of stylish aluminum cable trunking adapts to all your interiors: kitchens, offices, and perimeter wall installations. Recessed (RH1, RH2) or surface-mounted (SH1) models, available with or without low-voltage compartments, can be cut to size. Complete your installation with corners, end caps, RJ45 boxes, and mounting accessories, available in brushed aluminum or brushed black finishes.

Showing 8/13

Which EUBIQ trunking for your project?

Exposed cables, a layout to structure, a finish to perfect… In 4 questions, we will identify together the profile and accessories that truly match your situation.

Question 1 of 4

What is your main objective?

Question 2 of 4

What type of installation are you planning?

Question 3 of 4

Do you need to separate high-voltage and low-voltage in the same profile?

(High voltage = 230V power supply · Low voltage = network, phone, HDMI…)

Question 4 of 4

What is your priority for the final result?

Your personalized selection

Exposed cables along a wall, wires running behind a desk, haphazard power strips: cable trunking is often the simplest solution for restoring order. Still, you have to choose the right model. Between surface-mounted and flush-mounted profiles, brushed aluminum and black finishes, the differences are not just cosmetic. They dictate the ease of installation, cable capacity, and the final look in your interior.

And that is precisely where it gets complicated. Because with terms like "electrical molding," "wall cable cover," "cable skirting," and "cable trunking," it is easy to get lost. We will therefore unravel all of this together, compare the two main families of EUBIQ aluminum trunking, and help you find the configuration that really suits your project.

Trunking, molding, cable skirting: what really sets them apart

These three terms appear constantly in searches, yet they do not refer to the same thing. A quick overview to clarify.

  • Electrical molding: this is the small white PVC profile found everywhere in hardware stores. Designed to run 2 or 3 wires over a short distance, it helps in a pinch, but it doesn't do much more than that. Visually, let's be honest, it remains quite basic.
  • Cable trunking: wider section, higher capacity, and, above all, the possibility of separating high-voltage and low-voltage lines within the same profile. We are moving into another category - that of structured installations, designed to last and evolve. Materials vary: PVC, aluminum, sometimes steel.
  • Cable skirting: it replaces your classic baseboard and integrates a channel for wires. Discreet, yes. But not very modular, and not always compatible with the number of cables you want to tuck inside.

Where do EUBIQ aluminum trunking systems fit into all this? A notch above, frankly. The brushed aluminum finish provides a real aesthetic statement, and the modular system allows for the addition of accessories (sockets, RJ45, kitchen hooks) without DIY modifications. It is halfway between a professional electrical installation and designer furnishing - and that is precisely what makes them attractive for a well-appointed interior.

Surface-mounted or flush-mounted trunking: the comparison to help you choose

This is THE central question. And the answer depends as much on your project as it does on your technical constraints. At EUBIQ, two families coexist: the surface-mounted SH1 trunking and the flush-mounted RH2 trunking. Let's see what separates them in practical terms.

The surface-mounted SH1 trunking

It attaches directly to the wall, under a piece of furniture, or as a backsplash. Visible, yes - but far from the plastic white wall cable cover we try to forget. In brushed aluminum, the SH1 stands on its own as a full-fledged part of your layout. Its great strength: simplicity of installation. You fix it, you wire it, you close it. And if you need to add a cable six months later, everything remains accessible.

It is the natural choice for a desk strip, a kitchen backsplash, or framing a room when you want to avoid chasing walls.

The flush-mounted RH2 trunking

Here, the profile disappears into the surface: countertop, furniture, partition. Once installed, only the top face remains visible. The result is almost invisible, very clean. In return, you must plan for a cutout in the surface - which requires a bit more tooling and precision.

It is the ideal solution for integrated desks, kitchen islands, or any custom project where you want cables to disappear completely.

Comparison table

Criterion SH1 (surface) RH2 (flush)
Installation type Wall or under-furniture mounting Flush mounting in the surface
Installation difficulty Accessible (drilling + screwing) Intermediate (surface cutout required)
Visibility once installed Visible, designer finish Almost invisible
Cable access after installation Easy (removable cover) Easy (access from the top)
EUBIQ accessory compatibility Full (angles, covers, brackets, RJ45) Full (brackets, RJ45, caps)
Custom cutting Yes Yes
Finishes Brushed aluminum, brushed black Brushed aluminum
Typical usage Backsplash, desk strip, wall framing Countertop, island, integrated furniture

Good to know: both families share the same EUBIQ accessory ecosystem. RJ45 housings, high/low voltage separation brackets, end caps - everything is compatible. You are not locking yourself into a choice without a return path.

Four concrete situations, four different configurations

Theory is fine, but nothing beats real-world cases to visualize things. Here are four scenarios we often encounter - and the configuration that works for each.

In the kitchen: the multi-function backsplash

Imagine SH1 trunking installed as a backsplash, just above the countertop. It houses the cables for your small appliances (kettle, toaster, food processor), but that's not all. Thanks to EUBIQ accessories, you can clip on a support bar for utensils and kitchen hooks. The aluminum strip becomes both a cable-hiding trunk and storage. Two functions, one profile - it's smart.

At the office: the zero-cable workspace

Home offices are often beautiful desks ruined by a cluster of wires. The RH2 flush-mounted trunking changes the game: integrated into the desktop, it houses the monitor power supply, laptop charger, and desk lamp. Add a DS4 housing with an RJ45 Category 6E core for wired connectivity, and you get a clean workstation, with no cables visible. Honestly, it changes everything on a daily basis.

Framing a room: the alternative to chasing walls

Are you renovating a room and need to redistribute electricity without opening up the walls? The SH1 surface-mounted trunking along the walls does the job. With internal angles and external angles, the path hugs the room's corners neatly. End caps finish everything off. No dust, no plasterer, and a result that holds up aesthetically.

Mixed installation: separating high and low voltage

As soon as you have a power cable and a network cable cohabiting in the same trunking, you must consider separation. The high/low voltage separation bracket slides inside the profile and creates two distinct compartments. This is what the NF C 15-100 standard recommends, and it is primarily what prevents interference on your network connection. One bracket, one simple move, and your installation is up to code.

The accessories that make the difference during installation

This is often where the final quality of an installation is determined. Even an excellent electrical trunking system only provides an impeccable result if the finishing touches are up to par. And it is precisely on this point that the EUBIQ range stands out from generic PVC trunking.

  • SH1 internal and external angles: they avoid approximate 45° cuts and ensure a clean connection in every corner. The kind of detail that separates an amateur installation from a professional result.
  • SH1 end caps: sold in pairs, they neatly close each end of the trunking. Small accessory, big visual impact.
  • SFC2D cap: it allows you to neatly seal off a 100 cm section that you are not using yet. Practical when planning for a future extension.
  • SFC3 electrical segment: it is the one that powers the trunking. Without it, no outlets - it is essentially indispensable.
  • High/low voltage separation bracket (330 cm): available for SH1 and RH1 profiles, it is essential in any installation that mixes power and network.
  • RJ45 Category 6E core + DS4 housing: they transform your trunking into a network point. Ideal for an office or a shared workspace.

The common thread of all these accessories? They are designed to snap together without adaptation, without hacking, without double-sided tape reinforcement. This is not the case with generic trunking where you sometimes spend more time adapting the parts than installing them.

What to check before ordering

A few points of vigilance to avoid unpleasant surprises on installation day. Nothing difficult, but it is better to think about it beforehand.

  • Measure the required length precisely. EUBIQ trunking can be custom-cut, but always leave a little margin. Being short by 5 cm is frustrating.
  • Count your cables - and anticipate. How many wires today? And tomorrow, if you add a screen or an appliance? The rule of thumb: plan for 30% extra capacity. An undersized cable trunk is a trunk you will regret.
  • Flush-mounted = cutout. The RH2 requires a notch in the countertop or furniture. Plan for the appropriate tools (jigsaw, router) or call a carpenter. It is not a dealbreaker, but it is good to know in advance.
  • Electrical standards. Routing cables in trunking must comply with the NF C 15-100 standard, particularly regarding high/low voltage separation. We won't give you a full lecture here, but it is a point not to be neglected - especially if you mix power and computer networking.
  • Consistency of finishes. Brushed aluminum or brushed black, the choice is aesthetic. But make sure your angles, end caps, and caps are in the same finish. A detail that stands out when you forget it.

Frequently asked questions about electrical trunking

What is the difference between electrical trunking and molding?

Electrical molding is a small profile - usually in white PVC - designed to run 2 or 3 wires over short distances. Electrical trunking has a wider section, accommodates more cables, and often integrates a high/low voltage separation system. In aluminum, it also brings a real aesthetic dimension that PVC molding simply does not offer.

What size trunking should I choose?

Everything depends on the number and diameter of the cables to run. Count your wires, then plan for a margin of about 30% for possible future additions. For a classic office installation - power + network - an SH1 surface-mounted or RH2 flush-mounted trunk offers more than enough capacity.

Can I cut aluminum trunking to size?

Yes, EUBIQ trunking can be cut. Use a fine-toothed hacksaw or a circular saw equipped with a blade for aluminum. Remember to deburr the cuts with a fine file for a clean and safe result - cut aluminum edges can be sharp.

How can I hide cables on a wall without heavy construction work?

SH1-type surface-mounted trunking is the most direct solution. It attaches to the wall with a few screws, holds your cables, and closes cleanly. In a brushed aluminum finish, this wall cable cover integrates as a decorative element rather than a "cover-up." No chasing, no plaster, no repainting required.

Do I need to separate high-voltage and low-voltage cables in a trunk?

The NF C 15-100 standard recommends this separation to avoid electromagnetic interference. This is particularly important if you are running an RJ45 network cable and a power cable in the same trunking. EUBIQ separation brackets, available for SH1 and RH1 profiles, are designed exactly for this - they slide into the profile and create two sealed compartments.

Expert Advice