SH1 - Aluminium chute

  • Same profile as standard SH1 tracks – A bare-bones solution to build and customize your installation.
  • Custom lengths and room-specific layouts – Design the layout with the appropriate corners and connectors.
  • Electrify only the useful areas – Combine SFC3 segments with cut-to-size SFC2D end caps to achieve the desired length.

86,89 €

3x 28,96 €free of charge
Pay in 3 installments with Klarna
  • Free of Charge
  • Immediate response
  • 100% secure

In stock - Ready to be shipped

86,89 €

Same profile as SH1 railsCustomizable installationBrushed aluminum
SH1 — Customizable Aluminum Trackway

Choose your lengths and the areas to electrify

The SH1 trackway uses the same profile as the SH1 rails sold in 60, 80, 100, and 120 cm lengths. The difference: you design your own installation. Create a custom length, a corner return, or even a room perimeter trackway, electrifying only the useful areas with SFC3 segments and completing the other sections with SFC2D cut to the required length.

Standard SH1 rail or customizable SH1 trackway?

The same profile, two ways to prepare your project.

SH1 rails in standard lengths

SH1 rails are available in 60, 80, 100, and 120 cm lengths. Choose this solution when one of these lengths matches your layout.

Customizable SH1 trackway

Supplied bare in a 150 cm length that can be cut to size, the trackway allows you to customize the path, the final length, and the distribution of electrified areas. The components required for your configuration must be selected separately.

Design the installation you need

Electrify only certain areas

Position the SFC3 electrical segments where you want to use your EUBIQ outlets. It is not necessary to electrify the entire length of the installation.

Adjust the length with SFC2D

Complete the SFC3 segments with SFC2D blanking sections. The SFC2D can be cut to fill the non-electrified sections and achieve the desired final length.

Create returns and corners

Design a path suited to the room by selecting the necessary corners and connectors, rather than being limited to a standard straight length.

Create a room perimeter trackway

Run the trackway around the room and provide electrified areas only at useful locations: near a desk, cabinet, or workstation.

How to combine SFC3, SFC2D, and DS4?

Component Role in your installation
SH1 trackway The aluminum profile that forms the path of your installation.
SFC3 electrical segment Creates the electrified areas intended to receive EUBIQ outlets.
SFC2D blanking section Completes the non-electrified sections. It can be cut to adjust the overall length.
DS4 for RJ45 Allows RJ45 outlets to be installed at a fixed location between two SFC3 segments or at the end of the installation, instead of a section of SFC2D. Once installed, these RJ45 outlets cannot be moved along the track.
Corners and connectors Allow you to create changes in direction and junctions in the path.
End caps Close the ends of the trackway for a neat finish.

Example layout: along a long wall, provide an SFC3 area at the desk, another near a cabinet, then complete the intermediate sections with SFC2D. The path remains continuous, but only the chosen areas are electrified.

SH1 profile specifications

ProfileIdentical to the 60, 80, 100, and 120 cm SH1 rails
FinishBrushed aluminum
MaterialExtruded aluminum
Length offered on this data sheet150 cm — cuttable
SectionH 10 cm × D 2.85 cm
Compartments2 using the separation bracket
MountingSurface-mounted
BrandEUBIQ

Cable management and accessories

High-voltage and low-voltage wiring

The separation bracket creates two distinct compartments. The upper compartment can accommodate low-voltage cables, such as Ethernet.

Fixed RJ45 connections via DS4

RJ45 outlets are installed via DS4, between two SFC3 segments or at the end of the installation, instead of a section of SFC2D. They remain fixed and cannot be moved along the track. Plan their location when designing your installation.

Kitchen accessories

A groove under the profile allows bars or hooks to be clipped on to hang your utensils.

To be assembled separately: SFC3 segments, SFC2D blanking sections, DS4 for RJ45 outlets, corners, connectors, end caps, separation bracket, outlets, and other accessories according to your project. The bare trackway is not a pre-electrified rail.

Prepare your custom installation

1

Map out the path

Measure the lengths and changes in direction: straight section, corner return, or room perimeter trackway.

2

Identify the areas to electrify

Choose the locations of the SFC3 segments based on the devices you want to power. For RJ45 outlets, plan DS4 at fixed locations between two SFC3 segments or at the end of the installation, instead of a section of SFC2D.

3

Complete with SFC2D

Provide blanking sections for the non-electrified sections and cut them to achieve the desired final length.

4

Prepare the cuts and mounting

The aluminum trackway can be cut with a hacksaw. For a more professional cut, use a circular saw equipped with a blade suitable for aluminum. Secure the profile, follow the tool's safety instructions, and deburr the edges after cutting. Choose fasteners suitable for the mounting surface.

5

Assemble and connect

Follow the documentation for the various components for assembly and connection. The electrical installation must be carried out by a qualified electrician.

Frequently asked questions

Is the SH1 trackway different from the profile of the standard SH1 rails?

No, it uses the same profile as the SH1 rails sold in 60, 80, 100, and 120 cm lengths. The difference lies in the configuration: the bare trackway allows you to design the path and electrified areas according to your project.

Should the entire length be electrified?

No. Use the SFC3 segments at the locations where you need outlets and complete the other sections with SFC2D blanking sections.

How are RJ45 outlets installed?

RJ45 outlets are installed via DS4, between two SFC3 segments or at the end of the installation, instead of a section of SFC2D. They remain fixed and cannot be moved along the track.

How do you achieve a precise length?

Adapt the length of the trackway to your project, then complete the SFC3 segments with cut SFC2D to achieve the desired length. Do not confuse adjusting the blanking section with cutting the electrical segment.

Can you run it around a room?

Yes. The customizable solution allows you to create a room perimeter trackway with the necessary corners and connectors, electrifying only certain areas.

Is the black finish available for this product?

No. The trackway presented here is brushed aluminum.

Additional information

Reference5011-0807-0015
Weight indicated for this length1,900 g
Packaging dimensions155 × 10 × 3 cm

The SH1 profile, to your measure.

Design the path, choose your SFC3 areas, and adjust the SFC2D sections to your installation.

Characteristic Value
FinishingBrushed aluminum
Attachment typeSurface-mounted
Available lengths150 cm
BrandEUBIQ
Reference5011-0807-0015

FAQ9 Questions

FAQ – SH1 customizable track

How does it relate to the 60, 80, 100 and 120 cm SH1 tracks?

The SH1 track uses the same profile as these standard tracks. It is supplied bare and allows you to create your own installation by choosing the electrified areas and the final length.

How do you create a custom length?

Adapt the length of the track to your layout, then combine SFC3 electrical segments with SFC2D blanking plates. The SFC2D can be cut to complete the non-electrified sections and achieve the desired length.

Can you create a room perimeter?

Yes. With the necessary angles and connectors, the track allows you to create a layout around the room. You can electrify only certain areas with SFC3 segments and complete the other sections with SFC2D.

What length and finish are offered here?

This product sheet corresponds to a 150 cm cut-to-size SH1 track in brushed aluminium. It is not offered in a black finish on this product sheet.

How do you cut the aluminium profile?

A hacksaw is suitable. For a more professional cut, use a circular saw equipped with a blade suitable for aluminium. Hold the profile, follow the tool's safety instructions, and deburr the edges after cutting.

What accessories do you need?

Select the SFC3 segments, SFC2D blanking plates, DS4s for RJ45s, angles, connectors, end caps, separation flange, sockets, and other accessories required for your project. The end caps close the ends of the track. The bare track is not a pre-electrified rail.

How are the RJ45s installed?

The RJ45s are installed via the DS4s, between two SFC3 segments or at the end of the installation, in place of a section of SFC2D. They remain fixed and cannot be moved along the track. Plan their location when designing your installation. The upper compartment allows for low-voltage cabling.

Can you add kitchen accessories?

A lower groove allows you to clip on bars or hooks for kitchen utensils.

Who should perform the electrical connection?

The electrical installation must be carried out by a qualified electrician, following the documentation of the components used.

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Expert Advice

Mon–Fri 9am–6pm

Fast delivery

Home or pick-up point

GSS Patent

Maximum Security

WHAT OUR CLIENTS SAY ABOUT US

Discover below the reviews left by our hundreds of satisfied customers. These reviews come from verified buyers, and are controlled and verified by Judge.me, acting as a trusted third party between Eubiqeurope and its customers.

4.8 out of 5 stars based on 443 reviews.

Are you a professional ?

Electrician, fitter, furniture maker, kitchen designer...Apply for your professional account now to benefit from your conditions.